26-720
h)I) a receptacle shall not be placed in a cupboard, cabinet, or similar enclosure, except where the receptacle is
i) an integral part of a factory-built enclosure;
ii) provided for use with an appliance that is suitable for installation within the enclosure;
iii) intended only for a microwave oven;
iv) intended only for a cord-connected range hood; or
v) intended only for a cord-connected combination microwave oven/range hood fan;
i) except for cord-connected dishwashers, in-line water heaters, garbage disposal units, and other similar appliances, receptacles installed in cupboards, cabinets, or similar enclosures in accordance with Item h) ii) shall be de-energized unless the enclosure door is in the fully opened position;